Command Reference Guide Demand Interface Configuration Command Set
61200510L1-35E Copyright © 2005 ADTRAN 794

connect-sequence attempts <value>

Use the connect-sequence attempts command to limit the number of times the connect sequence will
cycle when its entries are unable to establish a connection. When the maximum number of attempts are
exhausted, the interface will go into recovery mode. Refer to connect-sequence interface-recovery
[retry-interval <seconds> | max-retries <value>] on page 795 for more information. Use the no form of
this command to restore the default values.
Syntax Description
<value> Specifies the number of times the connect sequence will cycle through its entries
if it is unable to make a connection. Range is 0 to 65,535.
Default Values
By default the connect-sequence attempts are unlimited.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.
Command History
Release 11.1 Command was introduced.
Usage Examples
The following example instructs demand interface 1 to attempt its connection sequence 500 times:
(config)#interface demand 1
(config-demand 1)#connect-sequence at tempts 500