Command Reference Guide ATM Sub-Interfa c e Config Command Set
61200510L1-35E Copyright © 2005 ADTRAN 729
dial-backup call-mode [answer | answer-always | originate |
originate-answer | originate-answer-always]
Use the dial-backup call-mode command to combine user data with pattern data to ensure data does not
mirror standard DDS loop codes (use only on 64 kbps circuits withou t Frame Relay sign aling). Use the no
form of this command to return to the default value.
Syntax Description
answer Answers and backs up primary link on failure.
answer-always Answers and backs up regardless of primary link state.
originate Originates backup call on primary link failure.
originate-answer Originates or answers call on primary link failure.
originate-answer-always Originates on failure; answers and backs up always.
Default Values
By default, the dial-backup call-mode role is set to originate-answer.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, and 4000 Series units.
Command History
Release 1.1 Command was introduced.
Release 8.1 ATM sub-interface was added.
Functional Notes
The majority of the configuration for Frame Relay dia l-backup is configured in the Frame Relay Interface
mode. However, the numbers dialed are configured in the primary interface. Full sample configurations
follow:
Sample configuration for remote router (dialing out)
hostname "Remote3200"
enable p assword adtran
!
interface eth 0/1
ip address 192.168.1 .254 255.255.255.0
no shutdown
!
interface modem 1/3
no shutdown
!