Command Reference Guide Frame Relay Interface Config Command Set
61200510L1-35E Copyright © 2005 ADTRAN 864
snmp trap link-status
Use the snmp trap link-status command to control the Simple Network Management Protocol (SNMP)
variable ifLinkUpDownTrapEnable (RFC2863) to enable (or disable) the interface to send SNMP traps
when there is an interface status change. Use the no form of this command to disable this trap.
Syntax Description
No subcommands.
Default Values
By default, the ifLinkUpDownTrapEnable OID is enabled for all interfaces except virtual Frame Relay
interfaces.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.
Command History
Release 1.1 Command was introduced.
Release 3.1 Command was extended to the SHDSL interface .
Release 5.1 Command was expanded to include Gigabit Ethernet, port channel, VLAN, E1,
and G.703 interfaces.
Functional Notes
The snmp trap link-status command is used to control the RFC2863 ifLinkUpDownTrapEnable OID (OID
number 1.3.6.1.2.1.31.1.1.1.14.0).
Usage Examples
The following example disables the link-status trap on the Frame Relay interface:
(config)#interface frame-relay 1
(config-fr 1)#no snmp trap link-status