Command Reference Guide Serial Interface Configuration Command Set
61200510L1-35E Copyright © 2005 ADTRAN 681

invert txclock

Use the invert txclock command to configure the serial interface to invert the transmit clock (found in the
transmitted data stream) before sending the signal. Use the no form of this command to return to the
default value.
Syntax Description
No subcommands.
Default Values
By default, the serial interfa ce does not invert transmit clock (txclock).
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, and 4000 Series and Total Access 900 Seri es units.
Command History
Release 1.1 Command was introduced.
Functional Notes
If the serial interface cable is long, causing a phase shift in the data, the transmit clock can be inverted
(using the invert txclock command). This switches the phase of the clock, wh ich co mpensates fo r a long
cable. If the transmit clock of the connected device is inverted, use the invert rxclock command to
configure the receiving interface appropriately.
Usage Examples
The following example configures the serial interface to invert the transmit clock:
(config)#interface serial 1/1
(config-ser 1/1)#invert txclock