Command Reference Guide G.703 Interface Configuration Command set
61200510L1-35E Copyright © 2005 ADTRAN 669

test-pattern [ones | zeros]

Use the test-pattern command to activate the built-in pattern generator and begin sending the specified
test pattern. This pattern generation can be used to verify a data path when used in conjunction with an
active loopback. Use the no form of this command to cease pattern generation.
Syntax Description
ones Generates a test pattern of continous ones.
zeros Generates a test patter n of continous zeros.
Default Values
No default s necessary for this command.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.
Command History
Release 5.1 Command was introduced.
Release 6.1 Command was expanded to include E1 and G.703 interfaces.
Usage Examples
The following example activates the pattern generator for a stream of continuous ones:
(config)#interface e1 1/2
(config-e1 1/2)#test-pattern ones