set summertime

Offsets the real-time clock of a DWS-1008 switch by +1 hour and returns it to standard time for daylight savings time or a similar summertime period that you set.

Syntax: set summertime summer-name [start week weekday month hour min end week weekday month hour min]

summer-name

Name of up to 32 alphanumeric characters that describes the

 

summertime offset. You can use a standard name or any name you

 

like.

start

Start of the time change period.

week

Week of the month to start or end the time change. Valid values are

 

first, second, third, fourth, or last.

weekday

Day of the week to start or end the time change. Valid values are

 

sun, mon, tue, wed, thu, fri, and sat.

month

Month of the year to start or end the time change. Valid values are

 

jan, feb, mar, apr, may, jun, jul, aug, sep, oct, nov, and dec.

hour

Hour to start or end the time change—a value between 0 and 23 on

 

the 24-hour clock.

min

Minute to start or end the time change—a value between 0 and 59.

end

End of the time change period.

Defaults: If you do not specify a start and end time, the system implements the time change starting at 2:00 a.m. on the first Sunday in April and ending at 2:00 a.m. on the last Sunday in October, according to the North American standard.

Access: Enabled.

Usage: You must first set the time zone with the set timezone command for the offset to work properly without the start and end values. Configure summertime before you set the time and date. Otherwise, summertime’s adjustment of the time will make the time incorrect, if the date is within the summertime period.

Examples: To enable summertime and set the summertime time zone to PDT (Pacific Daylight Time), type the following command:

DWS-1008# set summertime PDT success: change accepted

D-Link DWS-1008 CLI Manual

115

Page 118
Image 118