D-Link DWS-1008 CLI Manual 115
set summertime
Offsets the real-time clock of a DWS-1008 switch by +1 hour and returns it to standard time for
daylight savings time or a similar summertime period that you set.
Syntax: set summertime summer-name [start week weekday month hour min
end week weekday month hour min]
summer-name Name of up to 32 alphanumeric characters that describes the
summertime offset. You can use a standard name or any name you
like.
start Start of the time change period.
week Week of the month to start or end the time change. Valid values are
first, second, third, fourth, or last.
weekday Day of the week to start or end the time change. Valid values are
sun, mon, tue, wed, thu, fri, and sat.
month Month of the year to start or end the time change. Valid values are
jan, feb, mar, apr, may, jun, jul, aug, sep, oct, nov, and dec.
hour Hour to start or end the time change—a value between 0 and 23 on
the 24-hour clock.
min Minute to start or end the time change—a value between 0 and 59.
end End of the time change period.
Defaults: If you do not specify a start and end time, the system implements the time change
starting at 2:00 a.m. on the first Sunday in Apr il and ending at 2:00 a.m. on the last Sunday in
October, according to the North American standard.
Access: Enabled.
Usage: You must first set the time zone with the set timezone command for the offset to work
properly without the start and end values. Configure summertime before you set the time and
date. Otherwise, summertime’s adjustment of the time will make the time incorrect, if the date is
within the summertime period.
Examples: To enable summertime and set the summertime time zone to PDT (Pacific Daylight
Time), type the following command:
DWS-1008# set summertime PDT
success: change accepted