Field

Description

Product Name

DWS model number.

 

 

System Name

System name (factory default, or optionally configured with set system

 

name).

System Countrycode

Country-specific 802.11 code required for AP operation.

 

(configured with set system countrycode)

Total Power Over

Total power that the DWS-1008 is currently supplying to its directly connected

Ethernet

access points, in watts.

System Location

Record of the DWS switch’s physical location (optionally configured

 

with set system location).

System Contact

Contact information about the system administrator or another person to

 

contact about the system (optionally configured with set system contact).

System IP

Common interface, source, and default IP address for the DWS-1008, in

 

dotted decimal notation (configured with set system ip-address).

System idle timeout

Number of seconds MSS allows a CLI management session (console, Telnet,

 

or SSH) to remain idle before terminating the session. (The system idle

 

timeout can be configured using the set system idle-timeoutcommand.)

System MAC

DWS-1008 media access control (MAC) machine address set at the factory,

 

in 6-byte hexadecimal format.

Boot Time

Date and time of the last system reboot.

Uptime

Number of days, hours, minutes, and seconds that the switch has been

 

operating since its last restart.

Fan status

Operating status of the three switch cooling fans:

 

OK—Fan is operating.

 

Failed—Fan is not operating. MSS sends an alert to the system log every

 

5 minutes until this condition is corrected. Fan 1 is located nearest the front

 

of the chassis, and fan 3 is located nearest the back.

Temperature

Status of temperature sensors at three locations in the DWS-1008 switch:

 

ok—Temperature is within the acceptable range of 0° C to 50° C

 

(32° F to 122° F).

 

Alarm—Temperature is above or below the acceptable range. MSS

 

sends an alert to the system log every 5 minutes until this condition is

 

corrected.

PSU Status

Status of the lower and upper power supply units:

 

missing—Power supply is not installed or is inoperable.

 

• DC ok—Power supply is producing DC power.

 

• DC output failure—Power supply is not producing DC power. MSS

 

sends an alert to the system log every 5 minutes until this condition is

 

corrected.

 

• AC ok—Power supply is receiving AC power.

 

• AC not present—Power supply is not receiving AC power.

D-Link DWS-1008 CLI Manual