name

Service profile name.

threshold Number of times a radio can send the same short unicast frame. You can enter a value from 1 through 15.

Defaults: The default short unicast retry threshold is 5 attempts.

Access: Enabled.

Examples: The following command changes the short retry threshold for service profile sp1 to 3:

DWS-1008# set service-profile sp1 short-retry-count 3 success: change accepted.

See Also:

set radio-profile frag-threshold

set service-profile long-retry-count o

show service-profile

set service-profile soda agent-directory

Specifies the directory on the DWL-1008 switch where the SODA agent files for a service profile are located.

Syntax: set service-profile name soda agent-directory directory

name

Service profile name.

directory Directory on the DWS-1008 for SODA agent files.

Defaults: By default, the DWS-1008 expects SODA agent files to be located in a directory with the same name as the service profile.

Access: Enabled.

Usage: If the same SODA agent is used for multiple service profiles, you can use this command to specify a single directory for SODA agent files on the DWS-1008, rather than placing the same SODA agent files in a separate directory for each service profile.

Examples: The following command specifies soda-agent as the location for SODA agent files for service profile sp1:

DWS-1008# set service-profile sp1 soda agent-directorysoda-agentsuccess: change accepted.