Chapter 4 Managing Chassis

Chassis Fault Management

Chassis Fault Management

The Chassis Fault Management window displays general chassis availability details, Power Supply information, Temperature information, and Fan information. You cannot configure any parameters in the Chassis Fault Management window, it is a read only window.

The EM, for the chassis object, provides fault management of the overall management connectivity and the environmental aspects of the router. More details on management connectivity can be found in Chapter 18, “Fault Management.”.

Environmental fault management is provided in the form of four tables that report the status of Power Supplies, Voltage, Temperature and Fans within the chassis. Each table contains a State column that indicates the current state of each testpoint. This can be either Normal, Warning, Critical, Shutdown or Not Present. This functionality is supplemented by the processing of notifications from the Cisco 12000/10720 Router. See Chapter 18, “Fault Management,” for further information.

When an environmental fault is detected, then the recommended procedures documented at http://www.cisco.com/univercd/cc/td/doc/product/core/cis12000/cis12016/icg/hfricgtr.htm#xtocid5432 12 should be followed.

Note If the chassis object is deployed as a chassis of a different type then the chassis transits to the mismatch state and an appropriate alarm is raised.

The Chassis Fault Management section covers the following areas:

Viewing the Chassis Fault Management Window

Changing Column Width

Chassis Fault Management Window—Detailed Description

Viewing the Chassis Fault Management Window

To view the Chassis Fault Management window, proceed as follows:

Step 1 Right click on the chassis object and select the Fault>Fault Management option. See Table 4-1 on page 4-2for information on which objects allow you to launch the Chassis Fault Management window. The Chassis Fault Management window appears, with the General tab displayed.

Cisco 12000/10700 v3.1.1 Router Manager User Guide

4-20

OL-4455-01

 

 

Page 134
Image 134
Cisco Systems 12000/10700 V3.1.1 manual Viewing the Chassis Fault Management Window