4-28
Cisco 12000/10700 v3.1.1 Router Manager User Guide
OL-4455-01
Chapter 4 Managing Chassis
Command Log
Step 3 Scroll through the list of event commands, using the arrow bars, until the relevant event command
appears.
Note You can alter the width of the columns displayed in the table. See Changi ng Co l umn Width
section on page 4-24 for further details. The More (arrow) button is not applicable in this
window.

Com m and Log Wind owDetailed Descri ption

The Command Log window displays a single Command Log Details tab.

Command Log Details Tab

The Command Log Details tab (see Figure 4-14 on p age 4-2 7) displ ays a Comma nd Log Deta ils table
and Event History Details area.

Command Log Detail s Table

The Command Log Details table displays the following information:
IndexArbitrary integer value to uniquely identify the listed events. When it reaches the maximum
value, th e agen t wra ps th e value back to 1 and can fl ush exist ing ent rie s
TimeValue of system up time when the event occurred.
Comm and Source Source of th e comma nd that in stiga ted the ev en t. You will see eith er com mand Line
or SNMP.
Config SourceConfiguration data source for the event.
Config DestinationConfiguration data destination for the event.
Terminal TypeWhen the command source field is set to command line, the terminal type appears
(unknown, co nsole, ter minal , virtual or auxi liary). Otherw ise, not applic able ap pear s.
Terminal NumberWhen the command source field is set to command line, the terminal number
appears. When the terminal is not available or not applicable, -1 appears.
Terminal UserWhen the command source is set to command line, the name of the logged in user
appears. When the terminal type is not available or not applicable, the field appears empty.
Terminal LocationWhen the command source is set to command line, the hard-wired location of the
termin al or t he remo te host for a n incomi ng conn ection appear s. Wh en the ter mina l type is not a vailable
or not appli cable, the field appears em pty.
Command Source AddressWhen the terminal type field is set to virtual, the internet address of the
connected system appears. When the command source is set to SNMP, the internet address of the
requester appears.
V i rtual Host Name When the termi nal type f ield is set to virtu al, the host name of the connected sy stem
appears. When the terminal type is not available or not applicable, the field appears empty.
Server Address If Config Source (or) Config Destination field is 'networkTftp' or 'networkRcp', the
Internet address of the storage file server is displayed. The value is 0.0.0.0 if Conf ig Source (or) Config
Destination field is N/A.