Chapter 3 Getting Started
Deployment
Manually Deploying Supporting Modules
The Cisco 12000 Series Router chassis support the following supporting modules:
•Clock Scheduler Cards (CSCs)
•Switch Fabric Cards (SFCs)
•AC Power supply modules
•Fan tray modules
•Blower modules
Note The AC power supply, fan tray and blower modules can only be discovered during subchassis discovery (that is, they cannot be manually deployed).
The Cisco 12000 Series Router chassis supports the following CSC and SFC line cards. See Table
Table
Card | Card Type | Card Description |
|
|
|
CSC | CSC0 | OC48 Clock Scheduler Card |
|
|
|
| CSC4 | OC48 ClockScheduler Card |
|
|
|
| CSC8 | OC48 Clock Scheduler Card |
|
|
|
| CSC16 | OC48 Clock Scheduler Card for 12016 chassis |
|
|
|
| CSC16XOC192 | OC192 Clock Scheduler Card for 12416 chassis |
|
|
|
| CSC10XOC192 | OC192 Clock Scheduler Card for 12410 chassis |
|
|
|
| CSC6XOC192 | OC192 Clock Scheduler Card for 12406 chassis |
|
|
|
| CSCSFC64 | Combined |
|
|
|
SFC | SFC0 | OC48 Switch Fabric Card |
|
|
|
| SFC8 | OC48 Switch Fabric Card |
|
|
|
| SFC16 | OC48 Switch Fabric Card for 12016 chassis |
|
|
|
| SFC16XOC192 | OC192 Switch Fabric Card for 12416 chassis |
|
|
|
| SFC10XOC192 | OC192 Switch Fabric Card for 12410 chassis |
|
|
|
| SFC6XOC192 | OC192 Switch Fabric Card for 12406 chassis |
|
|
|
Deploying a Clock Scheduler Card
To deploy a clock scheduler card (CSC), proceed as follows:
Step 1 Right click on the chassis under which you want to deploy the CSC, then choose the correct CSC card from the service menu Deployment>Cisco 12000/10720 Manager>Module>CSC. The Deployment