5-109
Cisco VISM Installation and Configuration Guide
Release 3.0, Part Number OL-2521-01 Rev. D0, June 2004
Chapter5 CLI Commands
cnfcasparamsource
cnfcasparamsourceTo configure channel associated signaling (CAS)-related timer source parame ter s f o r an endp oint , use
the cnfcasparamsource command in the switched AAL2 PVC operating mode.
cnfcasparamsource endpt-num cas-source
Syntax Description
Command Modes Switched AAL2 PVC
Usage Guidelines You can configure different CAS-related timer values for different endpoints; however, the endpoints
must all be associated with the same CAS variant.
To use this command, you must ensure that the endpoint indicated by the endpt-num argument value has
been previously added, and that the associated DS0 is configured for CAS.
Examples The following example shows that endpoint number 100 is configured with CAS-related timer values
located in the current VISM card’s MIB:
cnfcasparamsource 100 2
endpt-num The endpoint number which is to be configured with the source location,
identified by the cas-source argument value. It can be a value from one of the
following ranges:
•For template number 1:
–
For VISM, from 1 to 145
–
For VISM-PR T1, from 1 to 192
–
For VISM-PR E1, from 1 to 248
•For template number 2:
–
For VISM T1, from 1 to 192
–
For VISM E1, from 1 to 248
•For template number 3:
–
For VISM, from 1 to 120
–
For VISM-PR T1, from 1 to 192
–
For VISM-PR E1, from 1 to 248
•For template number 4:
–
For VISM-PR, from 1 to 144
cas-source The CAS-related timer parameters source location. It can be one of the
following values:
•1 = CAS application file (Default)
•2 = Current VISM MIB