5-117
Cisco VISM Installation and Configuration Guide
Release 3.0, Part Number OL-2521-01 Rev. D0, June 2004
Chapter5 CLI Commands
cnfco4timer
cnfco4timer
To configure the bearer continuity test CO4 timer value, use the cnfco4timer command in the VoIP
switching/trunking and switched AAL2 PVC operating modes.
cnfco4timer co4-timeout
Syntax Description
Command Modes VoIP switching/trunking and switched AAL2 PVC
Usage Guidelines A timer is started when a CO3 or xRBK message is sent. If a CO4 message is not received before the
timeout expires, a VISM initiated DLCX message is sent to the call agent.
Examples The following example shows that the bearer continuity te st CO 4 timer expir es at 100 00 ms:
cnfco4timer 10000
Related Commands
co4-timeout It can be a value (defined in milliseconds) in the range from 50 to 10000. (Default =
1000)
Command Description
dspco4timer Displays the bearer continuity test CO4 timer value.
dspvismparam Displays the current VISM card configuration.