5-322
Cisco VISM Installation and Configuration Guide
Release 3.0, Part Number OL-2521-01 Rev. D0, June 2004
Chapter5 CLI Commands
dspcd
dspcd
To display the current VISM card’s configuration, status, and hardware and firmware configuration data,
use the dspcd command in the VoIP switching/trunking, switched AAL2 PVC, and AAL2 trunking
operating modes.
dspcd
Syntax Description This command has no arguments or keywords.
Command Modes VoIP switching/trunking, switched AAL2 PVC, and AAL2 trunking
Usage Guidelines T he VISM ca rd conf igur ation d ata disp layed i nclude s serial n umber an d hardw are and firmw are re vi sion
levels.
Examples The following example shows that the current VISM card configuration data is displayed:
dspcd
ModuleSlotNumber: 17
FunctionModuleState: Active
FunctionModuleType: VISM-8T1
FunctionModuleSerialNum: xxxxxxxxxx
FunctionModuleHWRev: 0.0
FunctionModuleFWRev: 1.5.0_11Nov01_2
FunctionModuleResetReason: ?
LineModuleType: LM-RJ48-8T1
LineModuleState: Present
mibVersionNumber: 21
configChangeTypeBitMap: CardCnfChng, LineCnfChng
pcb part no - (800 level): 800-xxxxx-xx
pcb part no - (73 level): 73-xxxxx-xx
Fab Part no - (28 level): 28-xxxxx-xx
PCB Revision: 08
Daughter Card Information:
Daughter Card Serial Number: xxxxxxxxxxx
pcb part no - (73 level): 73-xxxxx-xx
Fab Part no - (28 level): 28-xxxxx-xx
PCB Revision: 04
Related Commands Command Description
dspcds Displays a list of chassis card types, with associated slot numbers, card status, alarm
status, and redundancy status.
version Displays version-related information for a VISM card.