4-24
Cisco VISM Installation and Configuration Guide
Release 3.0, Part Number OL-2521-01 Rev. D0, June 2004
Chapter4 Configuring VISM Features
Configuring VISM Features
Note The cnfcasparamsource command permits different CAS-related timer values for different
endpoints, but all are associated with the same CAS variant.
Step 2 Type the cnfcasonhooktime command, endpt-num and onhooktime argument values, and press Enter to
specify the minimum time an on hook-pattern must be present to be recognized as an on-hook signal.
Specify the arguments with the following values:
endpt-num: Type the value used in Step 1.
onhooktime: In the range from 10 to 1000
Step 3 Type the cnfcasoffhooktime command, endpt-num and offhooktime argument values, and press Enter
to specify the minimum time an off-hook pattern must be present to be recognized as an off-hook signal.
Specify the arguments with the following values:
endpt-num: Type the value used in Step 1.
offhooktime: In the range from 10 to 1000
Step 4 Type the cnfcaswinktime command, endpt-num, min-make-time, max-make-time, and min-break-time
argument values, and press Enter to specify the minimum and maximum make times and the mi nimum
break time. A wink begins with an on-hook pattern, goes t o off-hook , an d r etur ns to o n-h ook . Spe cify
the arguments with the following values:
endpt-num: Type the value used in Step 1.
min-make-time: In the range from 10 to 1000
max-make-time: In the range from 10 to 3000
min-break-time: In the range from 10 to 1000
Note All three make and break duration time argument values must be observed for the signaling
sequence to be recognized as a wink.
Step 5 Type the cnfcasglaretime command, endpt-num and glaretime argument values, and press Enter to
specify the glare time. Specify the arguments with the following values:
endpt-num: Type the value used in Step 1.
glaretime: In the range from 10 to 1000
Step 6 Type the cnfcasguardtime command, endpt-num and guardtime argument values, and press Enter to
specify the guard time. Specify the arguments with the following values:
endpt-num: Type the value used in Step 1.
guardtime argument values:
In the range from 10 to 1000
Step 7 Type the cnfcasdialdelay command, endpt-num and dial-delay argument values and press Enter to
configure the CAS dial delay (wait time).
Dial delay is the time that VISM waits before sending dialing digits after sending an off-hook event.
Note The cnfcasdialdelay command applies to immediate start protocols only.
Specify the arguments with the following values: