SROS Command Line Interface Reference Guide

T1 Interface Configuration Command Set

 

 

clock source [internal line through through t1 <interface id>]

Use the clock source command to configure the source timing used for the interface. The clock specified using the clock source command is also the system master clock. Use the no form of this command to return to the default value.

Syntax Description

internal

Configures the unit to provide clocking using the internal oscillator.

line

Configures the unit to recover clocking from the primary circuit.

through

Configures the unit to recover clocking from the circuit connected to the DSX-1

 

interface.

through t1

Configures the unit to recover clocking from the circuit connected to the specified

<interface id>

T1 interface.

Default Values

By default, the clock source is set to line.

Command Modes

(config-t1 1/1)#

T1 or DSX-1 Interface Configuration Mode required.

(config-t1 1/2)#

 

Functional Notes

When operating on a circuit that is providing timing, setting the clock source to line can avoid errors such as Clock Slip Seconds (CSS).

Usage Examples

The following example configures the unit to recover clocking from the circuit:

(config)#interface t1 1/1

(config-t1 1/1)#clock source line

5991-2114

© Copyright 2005 Hewlett-Packard Development Company, L.P.

505

Page 505
Image 505
HP 7000 dl Router manual Clock source internal line through through t1 interface id, Internal, Through t1