ANR8817E Name length for volume Volumenameinvalid; max is Maximum name length.
Explanation: During LABEL LIBVOLprocessing, the volume name provided to
be written on the label exceeds the maximum length for the type of cartridge.
SystemAction: The label process fails for that cartridge.
User Response: Reissuethe LABEL LIBVOL command and provide a volume
name that is not longer than the maximum listed.
ANR8818E I/O Error on library library name; request for op. operation/function to the 3494
Library Manager has timed out.
Explanation: Acommand for the operation was issued to the Library Manager and
a response was not received within the maximum timeout period.
SystemAction: The operation and the transaction fails.
User Response: Verify that communications with the library is operational, that it
is online and ready for commands. Increase the time-out limit of the Library
Manager Control Point device driver.If the problem persists, provide your service
representative with the 3494 Library Manager transaction logs.
ANR8819E No barcode reader detected in librarylibrary name.
Explanation: ALABEL command was issued with the
LABELSOURCE=BARCODE option. The library was unable to detect that the
cartridges had valid barcode labels or the library did not have a barcode reader.If a
barcode reader is present the reader might be disabled or it is unable to read the
labels.
SystemAction: Examine the cartridges to ensure they have barcode labels and
they are compatible with the barcode reader.Not all vendors’ labels are readable by
all libraries. Check that the barcode reader is configured and functioning properly.
User Response: None.
ANR8820W Repairing VCR data for Volumevolume name in drive drive name; dismount
may be delayed.
Explanation: The VitalCartridge Records of the cartridge in the drive are lost or
corrupted, which results in the inability of the drive to do fast locates to file
positions on the cartridge. The VCR is being rebuilt during the volume dismount
process in order to avoid performance degradation on future mounts of the volume.
SystemAction: The server continues the dismount operation. There may be a long
delay because the VCR is rebuilt by spacing the tape forward to the end-of-data.
User Response: None.
1000
Version 3 Release 7