ANR8220W (Solaris)
TCP/IPdriver is unable to set the window size to TCPWindowsize for client
client. The default value will be used.
Explanation: The server cannot set the window size for the indicated client to the
requested size shown. The server uses the default window size for the indicated
session. There may be a lack of memory for TCP/IPbuffers.
SystemAction: Server operation continues and the session continues with the
default window size.
User Response: Retrythe session with a smaller window size in the options file.
Issue the QUERYOPTION command to determine the setting of the server
TCPWindowsize.
ANR8220W (Windows NT)
TCP/IPdriver is unable to contact node name due to an output socket
initialization error.
Explanation: The server attempts to contact the indicated node name. The attempt
is unsuccessful due to the inability to initialize a local socket.
SystemAction: The attempt to communicate with the indicated node fails.
User Response: Ensurethat TCP/IP is operating properly on this node and that it
can communicate remotely.Use the TCP/IP ping command for this purpose.
ANR8221W (AIX)TCP/IP driver is unable to use theTCP/IP NODELAY option for client client.
Explanation: The server cannot set TCP/IPNODELAY for the indicated client.
The session proceeds with TCP/IPDelay processing in effect. This causes TCP/IP to
buffer data prior to sending it to clients.
SystemAction: Server operation continues and the session continues with the
delay processing on.
User Response: Furtherdetails for use in contacting your service representative
can be obtained by issuing the following trace commands from an admin session or
from the server console (proper administrative authority is required): TRACE
ENABLE TCPINFO TRACE BEGIN.After a session starts and gets message
ANR8221W,issue the commands TRACE FLUSH TRACE END. This will create
trace data in file tcptrace.out and will terminate the trace. This file should be
supplied to your service representative on request.