ANR8236W (Windows NT)
Failure while listening for NETBIOS sessions on adapternetwork adapter
number, NETBIOS listen return code = listen returncode.
Explanation: The server cannot listen for NETBIOS sessions on the indicated
adapter.The indicated listen return code was received from the NETBIOS listen
API. If the return code is 24, (hex 18), the listen is retried.
SystemAction: Server operation continues. If the return code is 24 (hex 18), a
new listen is setup because return code 24 indicates a temporary failure. Otherwise,
no additional NETBIOS sessions will start using the indicated adapter until the
problem is corrected and the server is restarted.
User Response: ANETBIOS listen failure is an indication of a network problem,
an adapter problem, or a NETBIOS configuration problem. The following system
configuration and system environment listen return codes (in hex) and resolution
actions for a listen failure are found in the IBM Local AreaNetwork Technical
Reference:
Return
Code Description
11 The local session table is full. The maximum number of sessions are
in use. Change NETBIOS configuration to increase the maximum
number of sessions.
19 Name conflict. Ensure that the Server NETBIOS name is not in use
elsewhere on the network.
22 There are too many commands pending. The maximum number of
sessions are in use. Change NETBIOS configuration to increase the
maximum number of sessions.
35 The operating system resources are exhausted. Areboot is probably
required.
ANR8239I (AS/400)
HTTPdriver is ready for connection with clients on port port number.
Explanation: TheADSM server can accept sessions with clients using the HTTP
communication protocol on the indicated port number.
SystemAction: Server operation continues.
User Response: None.
838
Version 3 Release 7