ANR8294W (Windows NT)
Unable to establish IPX/SPX connection - accept error.Return code = tli error.
Explanation: The server cannot accept a client session due to a failure in
accepting the connection from IPX/SPX.
SystemAction: Server operation continues, but this session request fails.
User Response: Ensurethat SPX has been configured to run on this system
through the requester configuration program. Ensure that there is no other instance
of the server running on the same system that is using the same socket number.
Also ensure that the number of SPX sessions has not been exceeded through other
applications using the IPX/SPX protocol, such as NetWareapplications.
ANR8295W (AIX)Shared Memory driver unable to initialize due to error in BINDing to Port
port, reason code reasoncode.
Explanation: While initializing Shared Memory communications, the server failed
to connect to a master socket on which to listen for clients. The reason code is the
return code from the TCP/IPbind API.
SystemAction: Server operation continues, but the server cannot accept sessions
from clients using the Shared Memory protocol.
User Response: Ensurethat no application is using the port number specified in
the server options file with the SHMPORToption by issuing the TCP/IP netstat
command. If the server was brought down and client sessions were active, it may be
necessary to terminate the client sessions on the client systems before the port can
be freed.
ANR8295E (AS/400)
Command: Current license terms do not permit this operation.
Explanation: The specified command failed because the current license terms do
not permit it.
SystemAction: The operation fails.
User Response: Contactyour service representative to update the server license
terms so that the requested operation can be processed.
879
Tivoli Storage Manager Messages
3. Common and Platform
Specfic Messages