Completion Code Values Common to All Device
ClassesThe following table shows the completion code values, in decimal
and hexadecimal numbers, common to all device classes. It provides
a description for the I/O error message and the recommended action.
After performing the recommended action, retry the failing
operation. If the failing operation is not successful, contact TSM
support.
Table2. Completion Code Values Common to All Device Classes
Decimal Hexadecimal Description Recommended Action
200 X'C8' The device indicated a failure
condition, but sense data was
unavailable.
Retry the failing operation.
201 X'C9' Device driver failure Contact TSM support.
202 X'CA' Thedevice EEPROM failed. Thedevice should be tested or
serviced.
203 X'CB' Manualintervention required Correctthe problem on the device.
This may be a stuck tape, dirty
heads or a jammed library arm.
204 X'CC' Recoveredfrom an I/O error; for
your information only No action necessary
205 X'CD' SCSIadapter failure Check for loose cables, bent pins,
bad cables, bad SCSI adaptors,
improper termination or bad
terminators.
206 X'CE' GeneralSCSI failure Check for loose cables, bent pins,
bad cables, bad SCSI adaptors,
improper termination or bad
terminators.
207 X'CF' Device is not in a state capable of
performing request Ensure the device is on and ready.
Ensure the DEFINE DRIVE and
DEFINE DEVCLASS have been
issued properly.
208 X'D0' Command aborted Contact TSM support.
1393
Tivoli Storage Manager Messages
C. I/O Error Code
Descriptions