ANR0208W Partial write detected on recovery log volume volume name, logical page logical
page number (physical page physical page number).
Explanation: During a write of a recovery log page, an error occurs so that the
page is not completely written to disk.
SystemAction: The failed I/O operation is retried on a mirrored volume.
User Response: Seeaccompanying messages for information about the volume in
error.
ANR0209E Page address mismatch detected on recovery log volume volume name, logical
page logical page number (physical page physical page number); actual: logical
page number.
Explanation: During a read of a recovery log page, the page does not contain the
expected page address.
SystemAction: The failed I/O operation is retried on a mirrored volume.
User Response: Seeaccompanying messages for information about the volume in
error.
ANR0210S Inconsistency found in LVM data page page number - partial write detected.
Explanation: During a write of an LVMinternal page, an error occurs so that the
page is not completely written to disk.
SystemAction: The failed I/O operation is retried on a mirrored volume.
User Response: Seeaccompanying messages for information about the volume in
error.
ANR0211S Inconsistency found in LVM data page page number - page address mismatch
(actual page number).
Explanation: During a read of an LVMinternal page, the page does not contain
the expected page address.
SystemAction: The failed I/O operation is retried on a mirrored volume.
User Response: Seeaccompanying messages for information about the volume in
error.
ANR0212E Unable to read disk definition file file specification.
Explanation: At startup, the server cannot read the indicated file in order to obtain
a list of disk volumes to mount.
SystemAction: Server initialization fails.
22