User Response: Verifythe library manager is up and operational. Verify that the
library manager and library client can communicate using command routing.
ANR9781E Volservolume name was not found to be mounted on the library manager.
Explanation: According to the library manager the requested volume is no longer
mounted. The can occured if the library manager forced the volume to be
dismounted because of a communication error.
SystemAction: None.
User Response: Verifythat the volume has been dismounted.
ANR9782E Primary Library Manager primary library manager name is NOT defined as a
server.
Explanation: The primary library manager server has not be defined to this server.
SystemAction: None.
User Response: Define the server to this server using the DEFINE SERVER
command.
ANR9783E Primary Library Manager does not contain a valid value.
Explanation: The primary library manager server has not be defined to this server.
SystemAction: None.
User Response: Define the server to this server using the DEFINE SERVER
command.
ANR9784E Secondary Library Manager secondary library manager name is NOT defined as
a server.
Explanation: The secondary library manager server name has not be defined to
this server.
SystemAction: None.
User Response: Define the server to this server using the DEFINE SERVER
command.
ANR9785E Drive drive name, is not defined on the library manager.
Explanation: Adrive is being defined that does not exist or is being managed by
the library manager.
SystemAction: None.
1062
Version 3 Release 7