ANR8841I Remove volume from slot element number of library library name at your
convenience.
Explanation: Avolume has been placed in a multiple entry/exit port library
because the volume should be placed back in the entry/exit port as result of the
successful completion of a server command, or there was a problem during a server
command. The volume needs to be removed from the library,but the operation is
not critical.
SystemAction: None.
User Response: Removethe volume from the entry/exit slot. Examine previous
messages for additional information regarding the specified volume and the
command.
ANR8842E TheDevice type drive detected a marginal sector and could not reallocate the
sector for volume Volumename. Access mode is now set to read-only.
Explanation: The optical drive detected a marginal sector (media error) while
reading the volume. The drive read the sector successfully but could not reallocate
the sector because of a previous media error.
SystemAction: The volume is made read-only.
User Response: Checksystem error logs for entries made by the device relative to
media errors. It is recommended to move the data off the volume in order to
minimize the impact of future errors and further damage to the media.
ANR8846E Volume volume name is assigned to a category that does not belong to library
library name.
Explanation: The attempted operation on the volume cannot proceed because it is
assigned to a category other than the insert, private, or scratch category used by the
library.
SystemAction: The attempted operation is terminated.
User Response: Usethe mtlib utility to query the volume’s category. If the
volume is not in use by another library,use mtlib to reassign the category or choose
another volume that is assigned to the proper category.
ANR8847E Nodevice type-type drives are currently available in library library name.
Explanation: The attempted operation cannot be completed on the specified
library because there are no available drives of the specified type.A drive may be
unavailable because a different application has the drive opened. This message may
also be issued if a CHECKIN or LABEL command is issued and no drive is
1006
Version 3 Release 7