User Response: Reissue the audit command with FIX=YES so that the
information can be created or corrected.
ANR4272E Audit command: Missing or incorrect occupancy information detected -
information will be created or corrected.
Explanation: Adatabase audit process detects missing or incorrect occupancy
information for a data storage pool or a data storage volume. Because FIX=YES has
been specified for the audit command, the information will be created or corrected.
SystemAction: Audit processing continues.
User Response: None.
ANR4273E Audit command:A data-integrity error was detected on volume volume name -
Issue theAUDIT VOLUME command to correct the error.
Explanation: Adatabase audit process finds a data-integrity error for a file stored
on the specified volume.
SystemAction: Audit processing continues.
User Response: Issue theAUDIT VOLUME command on the specified volume to
correct the data-integrity error.
ANR4274E Audit command:A correctable data-integrity error was detected.
Explanation: Adatabase audit process finds a data-integrity error for a stored file.
This error can be corrected.
SystemAction: Audit processing continues.
User Response: Reissue the audit command and specify FIX=YES so that the
error can be corrected.
ANR4275E Audit command:A data-integrity error was detected - it will be corrected.
Explanation: Adatabase audit process finds a data-integrity error for a stored file.
Because FIX=YES has been specified for the audit command, the error will be
corrected.
SystemAction: Audit processing continues.
User Response: None.
550