Table 3-188. TEST #110 Data Channel Crosstalk Test
Error
Code
Test
Result Description/Recommendation
4 ABORT For this test, an Error Code of 4 can have one of two different meanings:
a. The target DATA-CHL is busy and, therefore, not available for use.
b. Internal system error
Determine if the target DATA-CHL is in use for some other function (that is,
CDR Link, System Printer Link, Journal Printer Link, PMS Link, or secondary
administration terminal connection) as described previously in the ‘‘Status of
Data Channels’’ section. If so, check for errors on the function that is using the
DATA-CHL. If there are no errors, there is a high probability that the
DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to completely test
the target DATA-CHL:
1. If the target DATA-CHL is in use for some other function, busyout the
function (CDR Link, System Printer Link, Journal Printer Li nk, P MS Link) or
the DATA-CHL (secondary administration terminal connection only).
2. Retry the command at 1-minute intervals a maximum of 5 times.
3. Restore any busied out CDR, S ystem Printer, Journal Printer, or PMS Lin k
to service before moving on to another activity.
40
70
75
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page