DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1050TBRI-PT (TN2185 ISDN Trunk-Side BRI Port)
3
Table 3-466. TEST #1244 Slip Alarm Inquiry Test
Error
Code Test Result Description/ Recommendation
ABORT Internal System Error
2000 ABORT Response to the test request was not received within the allowable time
period. If Error Type 1538 is present in the Error Log, follow the
maintenance strategy recommended for this error type.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1 to 88 FAIL The circuit pack and the remote endpoint are not synchronized to the
same clock rate, which has generated the Slip alarm. The error code
equals the number of slips detected by the TN2185 circuit p ack since
the last Slip Alarm Inquiry Test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the circuit pack is a TN2185, enter the list measurement ds1-log
PCSS command to read the error seconds measurement.
3. Verify that both endpoin ts of the DS1 link are administered using the
same signaling mode, framing mode, and line coding.
4. Check the physical connections of DS1 Interface circuit packs and
cable.
5. Replace the local DS1 Interface circuit pack and repeat the test.
6. Contact T1 Network Service to diagnose the remote DS1 endpoint.
PASS No Slip alarm is detected on the DS1 Interface circuit pack.
0 NO BOARD The DS1 Interface circuit p ack is not administered.
1. Administer the DS1 Interface circuit pack by issuing the add ds1
PCSS command.
2. Run the test again.
Continued on next page