DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-822MET-LINE (MET Line)

3
short in the loop or a defec tive voice terminal. Depend ing on what condition is sensed, a message is returned stating that either the EPF was turned on successfully with no prob lems or that an overcurrent cond ition is sensed. This test is repeated once more five sec onds later. If either test is not succ essful, the test aborts.Although this test will never actually retur n a fail result (except for the internal system error), an error type 257 entry will b e made in the error log when the test has completed if the overc urrent case is detec ted by the hardware.
Table 3-356. TEST #56 MET Electronic Power Feed Test
Error
Code
Test
Result Description/ Recommendation
ABORT The test was aborted due to an internal system error on a software
request to the board.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port
may be busy with a valid call. Use the display port PCSSpp command
to determine the station extension, attendant number, or trunk
group/member num b er of the port. Use the status station, status
attendant, or status trunk command to determine the service state of
the port. If the service state indicates that the port is in use, then the
port is unavailable for certain tests. You must wait until the port is idle
before retesting. Attendants are always in use (off-hook) if the handset
is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at 1-minute
intervals a maximum of 5 times.
FAIL The test failed with an internal error while it was attempting to turn on
the EPF.
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS EAF Test passed. The message to turn on the power to the station was
successfully sent to the port.
1. Although this test never returns a FAIL result, after running this test,
the Error Log should be checked for any entries with Error Type 257
to examine the real results of this test.
2. If Error Type 257 does not appear in the Error Log within 10
seconds after completion of this test, it is safe to assume that the
test sensed no problems with the power to the station. To verify that
the station is powered up correctly, run a self-test on the station, if
available, and check that all the feature buttons are operating.
3. If Error Type 257 appears in the Error Log, this indicates some
problem with the power to the station. The system technician
should check for a s hort in the wiring, a dama ged jack, a de fective
voice terminal, or an incorrect type of terminal.
Continued on next page