DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-74AN-LN-PT (Analog Line Port)
3
Aux Data 40975 indicates that the ter minal equipment was on-hook
when ring-tip was detec ted during ring ing. This usually indicates a
failure in the terminal equipment or the typ e of terminal has a low
ringer impedance.
1. Call the terminal equipment and verify that the terminal rings.
2. If the terminal does not ring, then rep lace it.
3. Otherwise, issue the test port UUCSSpp command, and
follow the procedure for Test #48.
40977 indicates that no terminal eq uipment was connec ted when
ringing was attempted .
1. Run the short test via the test port UUCSSpp command,
and follow the proced ure for the results of Test #48.
b. Error Type 15: this is a software audit error that does not ind icate any
hardware malfunction.
1. Run the Short Test Sequence and investigate any associated
errors.
c. Error Type 130: this error type indicates that the circuit pack has b een
removed or has been insane for more than 11 minutes .
1. To clear the error, reseat or replace the circuit p ack.
d. Error Type 257: this is an in-line error and can only be resolved over time.
This error indicates that ringing voltage is absent.
1. If only 1 analog circuit pa ck in the system has this problem, repla ce
the circuit pack.
2. If only analog circuit p acks on a partic ular carrier have this error,
the ringing generator may not be connected t o this carrier.
3. If analog circuit p acks on many carriers have this error, it is
probably a prob lem with the ringing g enerator.
e. Error Type 513:Test #48 can cause some terminal equipment to ring
briefly during d aily maintenance.
1. If this disturbs the c ustomer or the terminal equipment, disable it by
setting the Tests field on the change station
extension
form to n.
On some software releases, this also disable s Tests #6, 7, 161, and
35.