Maintenance Commands
2-83display system-parameters maintenance
2
Scheduled Maintenance
A series of maintenance tests and op erations runs automatically every day
according to the schedule and setting s specified in the following fields.
Start Time The hour and minute (24-hour notation) at which d aily scheduled
maintenance begins. (22:00 )
Stop Time Time (hour and minute) when scheduled daily maintenance stop s.
If any daily maintenance op erations are not completed b y this time,
the system notes where in the sequence i t stopped and p erform
those operations during the next scheduled d aily maintenance.
Daily
Maintenance This display-only field simp ly represents the series of tests that are
always run by maintenance software as p art of daily maintenance.
Save Translation This field indicates on whic h days translation data in memory will
automatically be saved to the Mass Storage System disk and/or
tape devices d uring scheduled maintenance. The save operation is
first made to disk, followed b y a disk backup to tape. On systems
with d upl icat ed SPEs, t ransl ation data is sav ed on both SPEs. Vali d
entries are daily, days of the week, or no. “No” spec ifies that no
automatic saves are to be exec uted. (daily)
Control Channel
Interchange Each port network has a pair of TDM busses called A and B, each
of which has a set of time slots ded icated to use by the c ontrol
channel. At any one time, the control c hannel in each PN is carried
on only one of the two busses. This field ind icates on which days
the control channel in eac h port network will be switched from one
of the paired TDM busses to the other. Valid entries ar e daily, days
of the week, or no. “No” sp ecifies that no interchange b e executed.
(no)
EXP-LINK
Interchange This field indicates whether or not the ex pansion links between
port-networks are interchang ed as part of sched uled maintenance.
The val ue “d aily '' me ans th at EXP-LI NK int ercha nge o ccu rs
autom atic ally e veryd ay. Th e valu e “no '' me ans th at EXP-LIN K
interchange is not done automatically as part of sched uled
maintenance. Values represented b y the days of the week mean
that EXP- LINK i nterc hang e occ urs a utoma tical ly on t he sp ecif ied
day only. Since EXP-LINK interchange only app lies to duplicated
systems, simplex systems do not display this field. (no)
Minimum
Threshold for
TTRs
When the number of touch tone receive rs (TTRs) in service falls
below this number (4 to 200), a WARNING alarm is raised ag ainst
TTR-LEV. These are also known as dual-tone multifreq uency
receivers (DTMRs). There are 8 TTRs on each TN2182. To alarm
the first occurrence of a TTR being taken out of service, set this