DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-81display system-parameters maintenance
2
Field descriptions
Defaults for data entry fields are listed in parentheses.
Product
Identification 10-digit number (starting with 1) that identifies the switch to an
Operations Support System (OSS), for example, INADS.
First OSS Telephone
Number First telephone number that the switch d ials to report alarms;
must be obtained from the Nat ional Customer Support Center
(NCSC) or the TSC. (# and * are not allowed in the telephone
number.)
Abbrev Alarm Report Enables the Abbreviated Alarm Report feature for the first OSS.
(yes)
Second OSS Telephone
Number Second telephone number th at the switch dials to report alarms;
must be obtained from the Nat ional Customer Support Center
(NCSC) or the TSC. (# and * are not allowed in the telephone
number.)
Abbrev Alarm Report Enables the Abbreviated Alarm Report feature for the second
OSS. (no )
Alarm Origination to
OSS Numbers One of four options for alarm originati on (neither):
If both, all Major and Minor alarms result in an automati c
call to both OSS telephone numbers. Bot h OSS telephone
numbers must be admini stered.
If first-only, all Major and Minor alarms result in an
automatic call to the first OSS number only. The switch does
not call the second OSS telephone nu mber even if the
number is administered. The first OSS telephone number
must be administered
If neither, alarm origination does not take p lace. Warning
alarms are not reported to either numb ers.
If second-as-backup, all Major and Minor alarms result in
an automatic call to the first OSS telephone numb er. If
calling the first OSS telephone number fa ils four attempts,
the switch starts to call the sec ond OSS telephone number
as a backup until c alling the first OSS telephone number
becomes succ essful. Both OSS telephone numbers must be
administered.
Before Release 5, the name of this field is Alarm
Origination Activated. If Alarm Origination is deac tivated,
both Cleared Alarm Notifica tion and Restart Notification are
disabled, even thoug h they may still be activated in the
administration.