DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-25ADX16D-P (16-Port AUDIX Digital Port)
3
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present, or some tone
detectors may be out-of-service.
1. Resolve any “TTR-LEV” errors.
2. Resolve any “TONE-PT” errors.
3. Retry the command at 1-minute intervals a maximum of 5 times.
1004 ABORT The port was put in use during the test. The test has been aborted. Use the
display port PCSSpp to determine the voice port extension of the port.
Use the status station command to determine the service state of the
port. If the port is in use, it is unavailable for certain tests. Wait until the port
is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 3-10. TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Code
Test
Result Description/Recommendation