DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1131TONE-BD (Tone-Clock Circuit Pack)
3
Notes:
a. Error Type 1 This error indicates the circuit pac k totally stopped
functioning or it was physic ally removed from the system.
NOTE:
The alarm is logged ap proximately 11 minutes after the circuit p ack
is removed/SAKI Sanity Test (#53) fails.
If the circuit pac k is not present in the system, insert a circu it pack in the
slot indicated b y the error to resolve the error.
If the circuit pac k is present in the system, it is faulty and must b e
replaced. See the prec eding section, ‘‘How to Replac e a Tone-Clock
Circuit Pack’’.
b. Error Type 18The indica ted Tone-Clock circuit pack has been made
unavailable via the busyout tone-clock PC command . This error applies
only to High or Critical Reliability syste ms (an active Tone-Clock may not
be busied out). To resolve this error, execute release tone-clock PC.
c. Error Type 23The circuit pack has b een logically adminis tered but not
physically installed. Ins talling the circuit pa ck will resolve the alarm.
d. Error Type 125A wrong circuit pack is inserted in the slot where this
circuit pack is logically administered . To resolve this problem, either
remove the wrong circuit pac k and insert the logic ally administered circuit
pack OR use the change circuit-pack command to read minister this slot
to match the circuit p ack inserted.
e. Error Type 126The port network specified in the PORT field of the error
log entry booted up without a Tone-Clock circuit pack, or with a one tha t
cannot communicate at al l with the system. The error is logged five
minutes after the port network is restarted . If no circuit pack is p resent,
install one of the proper cod e. If there is a circuit pac k present, replace it.
3872(p) 0 None set tone-clock PC
override
3999 (q) Any None
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the
set options command.
Table 3-497. Tone-Clock Circuit Pack Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value