DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-378CO-DS1 (DS1 CO Trunk)
3
1020 ABORT The test did not run due to a previously existing error on the specific port or
a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the already existing error.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2053 ABORT At least one of the following errors was found on the DS1 circuit pack: loss
of signal (1281), blue alarm (1793), red alarm (2049), yellow alarm (2305),
or hyperactivity (1537).
1. Look for the above error ty pes in the Hardware Error Log and f ollow the
procedures given in the appropriate DS1-BD or UDS1-BD
maintenance documentation for the listed error types.
FAIL The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots. User-reported troubles
on this port should be investigated using other port tests and examining
station, trunk, or external wiring.
Table 3-167. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page