DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-252ATM-TRK (Circuit Emulation Service Circuit Pack)
3
1144 ABORT Major alarm on the PPN packet bus
1. Run display alarms, and perform the repairs associated with PKT-BUS.
2. Run display errors, and perform the repairs associated with PKT-BUS.
3. Retry the command.
1394 ABORT ATM-TRK circuit pack out of service
1. Run ATM Board Reset Test #1256.
2000 ABORT Request timed out.
1. Retry the command up to 3 times at 1-minute intervals.
2060 ABORT Packet-bus link has failed.
1. Retry the command up to 3 times at 1-minute intervals.
2. If the test continues to abort, run display errors, and perform the repairs
associated with PKT-INT errors.
2100 ABORT Could not allocate the necessary system resources to run this test.
2500 ABORT Internal system error
1. Retry the command up to 3 times at 1-minute intervals.
1 FAIL Test tone not detected over the looparound; packet-path test aborted.
1. Test the active tone clock on the port network, and verify that a tone is
reaching the ATM-TRK circuit pack. If not, correct the condition.
2. Run test board UUCSS long.
3. If the test continues to fail, replace the ATM-TRK circuit pack or
transceiver.
4. Rerun test board UUCSS long.
2 FAIL TN1655 Packet Interface circuit pack could not detec t the correct data
packet.
1. Test the TN1655 P acket Interface circuit pack to verify that it is functioning
properly. If not, correct the condition.
2. Run display errors, and perform the repairs associated with DS1
CONV-BD errors, if applicable.
3. Run display alarms, and perform the repairs associated with DS1
CONV-BD alarms, if applicable.
4. Run test board UUCSS long.
5. If this test continues to fail, replace the ATM-TRK circuit pack.
6. Run test board UUCSS long.
Table 3-111. ATM Board Framer Looparound Test (#1260) — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page