DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-8How to use the Maintenance book
1
Screen 1-2. Alarm Report screen
A DID trunk port in slot 10, carrier C has a MAJOR alarm.
5. Note the value in the Port field (01C1008). This is the alarmed port
address.
6. Type display errors and press Enter.
7. A query screen disp lays next, asking if you want to see all the errors or if
you want to restrict the list to certain kind s of errors. Except for warning
levels (Major, Minor, Warning), the screen is the same as Screen 1-1 .
Generally, unless you suspect a problem occurred within a c ertain time
frame or with a particular c omponent of the system, simply p ressing Enter
at the query screen disp lays the accumulated system errors (Screen 1-3).
Screen 1-3. Hardware Error Report - Active Al arms
8. Note the Error Type (Err Type field) value (1547) and the Aux Data
value if present.
9. Find the DID-TRK MO in the Maintenance Object c hapter of the
appropriate maintenanc e book.
10. In the first table look up the initial c ommand to run in the MAJOR row of the
table (Step 4 indicated that a DID trunk in slot 10, carrier C has a MAJOR
alarm).
MO Name (in
Alarm Log) Alarm Level Initial Command to Run1
1.
UU
is the universal cabinet number (1 for PPN, 2 - 44 for EPNs),
C
is the carrier designation (A, B,
C, D, or E),
SS
is the number of the slot in which the circuit pack resides (01 to 21), and
pp
is the
two digit port number (01, 02, ...).
Full Name of MO
DID-TRK MAJOR2test port UUCSSpp long DID Trunk
DID-TRK MINOR test port UUCSSpp long DID Trunk
DID-TRK WARNING test port UUCSSpp DID Trunk
ALARM REPORT
Port Maintenance On Alt Alarm Svc Ack? Date Date
Name Brd? Name Type State 1 2 Alarmed Resolved
01C1008 DID-TRK y MAJOR 03/09/00:30 00/00/00:00
HARDWARE ERROR REPORT - ACTIVE ALARMS
Port Mtce Alt Err Aux First Last Err Err Rt/ Al Ac
Name Name Type Data Occur Occur Cnt Rt Hr St
01C1008 DID-TRK 1547 03/09/00:20 03/15/01:18 255 1 7 a y