DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-268BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)
3
BRI-PORT (ISDN-BRI Port),ABRI-PORT (ASAI ISDN-BRI Port)
NOTE:

Some of the information in this section is reserved for futu re use.

!WARNING:

If a significant Packet Bus failure oc curs, errors and alarms may not b e

logged as exp ected for

BRI-PORT/ABRI-PORT/ATT-PORT/LGATE-PT/ATTE-PT.

The TN2208 LGATE MFB provides DEFINITY with the interface to Adjunct-Switch

Application Interf ace (ASAI) and Lucent adjunc ts (for example, CONVERSANT®.

Voice System). The circuit pack contains 12 p orts of line circuit interfa ce

(although only 8 are usable by the switch), each of which op erates with two

B-channels (referred to as B1 and B2 throug hout this section) and one D-c hannel

MO Name (in
Alarm Log) Alarm Level
Initial Command to
Run1
1. Where P is the port network number (1 for PPN); C i s the carrier designation (A, B, or C); and
SS is the address of the slot in the carrier where the circuit pack is located (01, 02, ..., etc.);
and pp is the 2-digit port number (for example, 01).
Full Name of MO
BRI-PORT MINOR test p ort PCSSp p l ISDN-BRI Port
BRI-PORT WARNING test port PCSSpp sh ISDN-BRI Port
ABRI-PORT MAJOR2,3
2. The alarm level for ASAI and Lucent adjunct ports may be administered using the set
options command. The alarm level can be set independently for Off-Board and On-Board
alarms to WARNING, MINOR , o r MAJ OR for all ASAI and Lucent adjunct ports in the system.
3. All alarming for an ASAI and Lucent adjunct and OFF-BOARD alarming for an ASAI or Lucent
port is disabled if the ASAI or Lucent adjunct asks the switch to suspend maintenance. When
this occurs, an error and a WARNING alarm is logged ag ainst the ASAI or Lucent adj unct.
The Hardware Error and Alarm Logs should be checked to see if the adjunct has disabled
alarming.
test port PCSSpp l ASAI ISDN-BRI Port
ABRI-PORT WA RNING2,3test port PCSSpp l ASAI ISDN-BRI Port
ATT-PORT MAJOR2, 3test port PCSSpp l Lucent Adjunct ISDN-BRI Port
ATT-PORT WARNI NG2, 3test port PCSSpp l Lucent Adjunct ISDN-BRI Port
LGATE-PORT M AJOR2, 3test port PCSSpp l Ethernet ASAI Port
LGATE-PORT WA RNING2, 3test port PCSSpp l Ethernet ASAI Port
ATTE-PT MAJOR2, 3test port PCSSpp l Ethernet Lucent Adjunct Port