DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-302status sys-link
2
Output
The following example shows the output for the status synchronization
command.
Field descriptions
status sys-link
This command displays status data for a specified system link. The report
includes the type and operational state of the link, the assoc iated processor
channel (if any), active alarms and path status, and a list of al l hardware
components making up the link’s path.
Stratum Level Synchronization stratum level (3 or 4)
Maintenance
Name: Either TONE-BD, DS1-BD, or STRAT-3.
Physical
Location Board location of the selec ted DS1 or tone-clock cir cuit pack
(cabinet-carrier-slot for a DS1; cab inet-carrier for a tone-clo ck)
Switching
Capability Whether the on-line reference for synchronization can be switched
(Enabled or Disabled)
Excessive
Reference
Switching
High-level descrip tion of how many times the synchronization
reference has been switc hed. If excessive referenc e switching is
taking place (sync error 1793 is at threshold), this field displays
Yes; otherwise No displays.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status sys-link
location
Port location: PCSSpp
Example:
status sys-link 1b0201
init
inads
craft
none none
status synchronization
SYNCHRONIZATION STATUS
Stratum Level:4
Maintenance Name: TONE-BD Physical Location: 01A
Switching Capability: Enabled
Excessive Reference Switching: No