DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-215ATM-SGRP (ATM Signaling Group)

3
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order p resented in the table below whe n inspecting errors in the sy stem. By clearing error cod es associated with the Primary Signaling Link Hardware Check, for ex ample, you may also clear errors generated from other tests in the testing sequence.
3906 Protocol detail; may offer a
clue if customer is having
ISDN calls denied with an
unexpected intercept tone.
1. If customer is complaining of unexpected intercept
tones when accessing ISDN trunks or PRI endpoints
and no other cause c an be found, escalat e to the
problem and provide the next tier with this Error Log
information.
3909 A request to use a network
service has been made,
but the network has
rejected the request
because the requested
service is not implement ed.
1. Follow the recommendations listed above for Error
Type 3890.
3928 A call was denied because
of a basic incompatibility
between the type of call
and either the facilities
selected by the routing
pattern or the called user
itself.
This error might be helpful as a clue if the customer
complains of receiving unexpected interc ept tone after
accessing ISDN trunks or PRI endpoints.
1. Determine the trunk group from the circuit pack and
port number (in the aux data field)
2. check the BCC fields of the pertinent routing
patterns.
3. Also, investigate whether or not the calling and called
endpoints are compatible (for example, some ISDN
switches may not allow a voice station to call a data
extension).
Table 3-88. Descriptions and repair recommendations (Error Types 3840-3928) — Continued
Error
Code Description Recommendation