DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-12busyout port
2
Output
The following example is a display of the busyout pms-link command.
Field descriptions
busyout port
This command places the sp ecified port on a c ircuit pack in a maintenanc e busy
state. No periodic or sc heduled tests are performed on the busied out port until it
is released. When the object is maintenanc e busy, it is deactivated (no c all
processing ac tivity may include the busied object). Warning alarms (error type
18) are generated on each b usied out maintenance objec t, so that INADS can
determine the state of the objec ts. The command, release port, reactivates the
administered port on a c ircuit pack at a sp ecified location.
Port Always blank
Maintenance Name Name of maintenance objec t: PMS-LINK
Alt. Name Not applicable.
Result Test result: Pass, Abort, Fail
Error Code Numeric code exp laining why the release failed or aborted . Refer
to the detailed list of the co des by test number for each MO.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout port
location
Port address: PCSS
marked port: PPSSpp
Examples:
busyout port 01c1101
busyout port 02c1501
init
inads
craft
none see below
busyout pms-link SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
PMS-LINK PASS
Command Successfully Completed