DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-418CUST-ALM (Customer-Provided Alarming Device)
3
Table 3-179. TEST #115 Customer-Provided Alarming Device Test
Error
Code
Test
Result Description/Recommendation
(blank)
1000
2029
ABORT Internal system error
1. Try the command at 1-minute intervals a maximum of 5 times.
PASS The switch software successfully sent the request to the Processor circuit
pack to turn on the CPAD. The CPAD must be physically inspected to
verify that it is working. If the CPAD is working and the customer has
complained that the CPAD did not indicate a system alarm when it
occurred, then check the administered levels for turning on the CPAD via
the Display System-Parameter Maintenance screen form. Compare these
levels with the customer’s specifications. If Test #115 passes, and the
CPAD is not being activated, check the connection of the CPAD to the
Processor circuit pack. If the CPAD can be activated but c annot be
deactivated, first check to make sure Emergency Transfer is not activated
in the affected port network via the status system command. Emergency
Transfer can be forced to manual OFF by the Emergency Transfer switch
on the Processor circuit pack. If Emergency Transfer is OFF and the CPAD
still cannot be deactivated, check the ad ministered levels for the CPAD
with the Display System-Parameter Maintenance screen form and
compare against the alarm levels currently present in the system (display
alarms command).