DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-721ISDN-SGR (ISDN-PRI Signaling Group)

3
Error Log Entries and Test to Clear Values
Notes:
a. This switch sent a message to the far-end switc h or terminal adapter, and the far-end did not resp ond in the allotted time. Possible c auses include link failure and congestion or o utage at the far-end. The Aux Data field contains Layer 3 protocol infor mation used by internal c ounters.If no other symptoms are not present, no ac tion is required. If Layer 3 communication is down, there shou ld be indicati ons in the form of alarms and errors for link components. Chec k out other errors against ISDN-SGR, ISDN-TRK, and other hardware components on the link.
Table 3-302. ISDN-PRI Signaling Group Error Log Entries
Error
Codes
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short or Long Test Sequence. Refer to the appropriate test description and follow the
recommended procedures.
0 Any Any test sig-group
<group>
1 (a) Any none
257 (b) Any none test sig-group
<group>
513 (c) Any none test sig-group
<group>
769 Any Primary Sig naling
Link Hardware Check
(#636)
test sig-group
<group>
1025 Any Secondary Signaling
Link Hardware Check
(#639)
test sig-group
<group>
1793 (d) Any Layer 2 Status (Test
#647) WARNING OFF test sig-group
<group>
2049 (e) Any Layer 2 Status (Test
#647) WARNING OFF test sig-group
<group>
2305 (f) Any Remote Layer 3
Query (Test #637) MINOR OFF test sig-group
<group>
3585 (g) port
number none none
3840-
3928 (h) port
number none