DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-942PR-MAINT (Maintenance Processor)
3
Error Log Entries and Test to Clear Values
Notes:
a. The MTP Reset Test (#101) has failed.
b. The MTP Sanity Handshake Test (#106) has failed.
c. The MTP Analog Loop Around Test (#103) has failed.
d. The MTP Dual Port Ram Test (#104) has failed. An error of 769 with an aux
data of 5 indicates a hard ware problem and testing will not clear it. The
circuit pack should be replac ed.
e. The MTP Outpulse Relay Test (#102) has failed.
f. The MTP Manager I Loop Around Test (#228) has failed.
g. The MTP Aux Loop Around Test (#229) has failed.
NOTE:
Refer to the FAIL section of each test that fails for further instructions.
Table 3-406. Maintenance/Tape Processor Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value1
1. You must manually repeat the command with the "long" option the designated number of times from
the administration terminal or from a remote administration terminal because the Sanity Timer Test
(#83) logs you off.
02
2. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test processor a/b sh r 1
1 (a) Any MTP Reset Test (#101) MIN ON test processor a/b l r 3
257 (b) Any MTP Sanity Handshake Test
(#106) test processor a/b r 2
513 (c) Any MTP Analog Loop Around
Test (#103) MIN ON test processor a/b r 8
769 (d) Any MTP Dual Port Ram Test
(#104) MIN ON test processor a/b l r 3
1025 (e) Any MTP Outpulse Relay Test
(#102) MIN OFF test processor a/b r 5
1537 (f) Any MTP Manager I Loop Around
Test (#228) MIN ON test processor a/b r 3
1793 (g) Any MTP Aux Loop Around Test
(#229) MIN ON test processor a/b r 3