DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-944PR-MAINT (Maintenance Processor)

3
MTP Reset Test (#101)

This test is destructive. The test resets the Maintenance/Tape Processor. The

destructive nature of this test c auses the following:

Administration terminal to log off
CDR port to terminate data transmission
Any current tape acc ess to terminate and also to tear down any remote

access INADS connection

Table 3-407. TEST #101 MTP Reset Test
Error
Code
Test
Result Description/ Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to STBY-SPE Maintenance documentation for a description of these
error codes.
10102 ABORT System software resources required for this test are not available.
10104 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
10105 FAIL The MTP did not respond to being reset.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, replace the Processor circuit pack.
10106 FAIL The Maintenance/Tape Processor was reset, but it responded with a NOT
PASS status, indicating that it did not pass initialization correctly. The MTP
is not functioning correctly. The system should continue to function, but it
will not have the ability to save translation to tape, or to read tape if the
system needs to be rebooted. Environmental monitoring is lost, as is
communication with the Stand by Processor.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If test continues to fail, replace the Processor circuit pack.
Continued on next page