DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-506DIG-LINE (Digital Line)
3
Hardware Error Log Entries and Test to Clear
Valu es
Table 3-213. DIG-LINE Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any t est port PCSSpp sh r 1
1 (a) 40987 None WARNING OFF
1 (b) 1 to 20 None WARNING OFF
18 (c) 0 busyout port
PCSSpp WARNING OFF rel port PCSSpp
130 (d ) None WARNI NG ON test port PCSSpp sh
257 (e) 40971 None
513 0 Station (Digital)
Audits Test (#17) WA RNING(
o) OFF test po rt PCSSpp sh r 6
767 (f) 40964 None WARNING OFF
769 (g) 40963
40988 None WARNING OFF
1026(o) NONE WARNING OFF
1281 Any Station (Digital)
Audits Test (#17) WARN ING OFF tes t port PC SSpp sh r 4
1537 (h) 40968 None WARNING OFF
1793 Voice & Ctrl. Local
Loop Test (#13) MINOR/
WARNING 2
2. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
ON test p ort PCSSpp l r 3
2049 NPE Crosstalk Test
(#9) MINOR/
WARNING 3
3. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
ON test p ort PCSSpp l r 3
2304 (n) None
2305 (i) 32770 None
2305 (h) 40967 None
3840 (k) 40965 None
3840 (l) 40989 None
3841 (m) 41029 None
Continued on next page