DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-131ATM-BCH (ATM B-Channel Trunk)
3
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate problems in the order presented in the tab le below. When you
clear one of the error codes asso ciated with a given test, you c lear errors
generated by other tests in t he testing sequence. If you clear errors out of order,
you can lose important infor mation.
Signaling Link State Audit Test (#255)
This non-destructive test chec ks the status of the TN230x ATM-CES Interface
circuit pack and the ATM D-channel (ATM-DCH) trunk, which are both important
elements to the health of the ATM-BCH trunk.
Table 3-52. System Technician-Demanded Tests: ATM-BCH
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Destructive or
Non-destructive
Signaling Link State Check Test (#255) X X ND
Service State Audit Test (#256) X X ND
Call State Audit Test (#257) X X ND
ISDN Test Call Test (#258) X ND
Continued on next page
Table 3-53. TEST #255 Signaling Link State Audit Test
Error
Code
Test
Result Description/ Recommendation
None ABORT Internal system error
0 ABORT
1114 ABORT Signaling link in transitional state
1. Retry the command up to 5 times at 1-minute intervals.
1018 ABORT Maintenance disabled
1. Enable maintenance. Enter y in the Maintenance Tests? field on
page 2 of the change trunk-group for m.
Continued on next page