DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-121list measurements ds-1
2
Field descriptions
list measurements ds-1
This command lists perform ance measurements of a DS-1 link indicating the
quality of the DS-1 physical interfac e between the system and a far en d system.
The ds1 summary op tion provides a summary rep ort while the ds1 log option
provides a detailed report.
NOTE:
The list measurements command has many more options than
documented here. Only those op tions dealing with DS1 board are
documented b elow.
Date The date that the data was collec ted
Time The current 15-minute interval in which the action was performed
CRC Check The error count for CRC errors
Total Total value of the board counter.
NOTE:
The counter value can be up to 7 d igits long bec ause the 16-
bit counter on the board . After the occurrence of an “ N/A” the
delta equals the total. Busyout or release of a b oard or a port,
the reset board command, and reseating the board all c lear
the firmware counters.
Delta The difference between the cur rent and the previous sampl e
Invalid Frame The number of invalid frames detec ted. Invalid frames are the
frames that are misaligned.
CHAP Failures The number of failed attempts for ppp authentication
list measurements clan ppp 1C1001 Page 1 of x
Switch Name: sierra Date:02/02/1999
C-LAN PPP PERFORMANCE MEASUREMENT DETAILED REPORT
Date Time CRC Check Invalid Frame CHAP Failures
Total Delta Total Delta Total ‘Delta
02/01 03:08 85 25 185 85 5 0
02/01 02:53 60 60 100 100 5 5
02/01 02:38 N/A N/A N/A N/A N/A N/A
02/01 02:23 1000060 10 1000090 10 25 5
02/01 02:08 1000050 1000050 1000080 1000080 20 20