DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1137TONE-BD (Tone-Clock Circuit Pack)
3
Notes:
a. Refer to XXX-BD (Common Port Circuit Pack) documentation for
descriptions of these tests.
b. Refer to TONE-PT (Tone Generator) documentation for d escriptions of
these tests.
Notes:
a. Refer to XXX-BD for descriptions of these tests.
b. Refer to TONE-PT for descriptions of these tests.
c. Refer to TDM-CLK for descriptions of these tes ts.
Clock Health Inquiry Test (#46)
This inquiry reads spec ial data stored in memory to d etermine if this Tone-Clock
circuit pack had a loss of any of three clock typ es:
SYSCLK
SYSFM
SYSDCLK
Table 3-499. System Technician-Demanded Tests:
TONE-BD (TN2182 only)
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND1
1. D = Destructive, ND = Non-destruc tive
SAKI Reset Test (#53) (a) X
Clock Health Inquiry Test (#46) X X
Control Channel Loop Around Test (#52) (a) X X
Tone Generator Crosstalk Test (#90) (b) X
Tone Generator Transmission Test (#40) (b) X X
Tone Generator Audit/Update (#41) (b) X X
TDM Bus Clock Circuit Status Inquiry Test (#148) (c) X X
TDM Bus Clock Slip Inquiry (#149) (c) X X
TDM Bus Clock PPM Inquiry Test (#150) (c) X X
TDM Bus Clock Parameter Update Test (#151) (c) X X
Board Type Check Test (#574) (c) X X
Standby Reference Health Check Test (#651) (c,) X