The TN793B/TN2793B Analog Line circuit pack (w/ Calle r ID), and the TN797
Analog Trunk and Line circuit pac k both support thi s Maintenance Object.
The TN793B/TN2793B Analog Line circuit pack (w / Caller ID) provides 24 ports
for voice terminals and sup ports both on-premises and off-premises analog
voice terminals.
The TN797 Analog Trunk and Line circuit pack p rovides 8 ports, each o f which
may be administered in any of several ways, as described in maintenance object
TR-LN-B D.
NOTE:
The TN793B/TN2793B analog line circuit pack supports analog d ata
modules. When assigned, analog data modules p rovide access to the
NetPkt (TN794 circuit pack) data p orts. To activate an analog data module
you must assign the port loc ation on the data form and c onnect a modem
to the port. The analog data mod ule can be used for connection to a CDR
output, or other adjuncts as ne eded. These ports are tested the sam e as all
other analog ports on the c ircuit pack.

Ringing caused by maintenance testing

Test #48 may cause some terminal equipment to ring briefly during d aily
maintenance. If this ringing d isturbs the customer or the t erminal equipment,
disable it in t he Tests field of the change station
extension
form. Be aware that
this action also disables Tests #6, 7, 161, and 35 on some softwa re releases.
MO Name (in
Alarm Log) Alarm Level
Initial Command to
Run1
1. UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pac k resides
(01 to 21). pp is the two digit port number (01, 02, ...).
Full Name of MO
AN-LN-PT MIN test port UUCSSpp l Analog Line Port
AN-LN-PT WRN test port UUCSSpp sh Analog Line Port