DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-73AN-LN-PT (Analog Line Port)

3
Error log entries and test to clear values
Notes:
a. Error Type 1: these are in-line errors and can only be resolv ed over time.
Aux Data 40960 indicates that too many s imultaneous incoming
ringing attempts were made on this board. O nly 4 ports on a board may ring simultaneously. A 5th incoming c all will cause an inline error from the board.Table 3-29. Analog line error log entries
Error
Type
Aux
Data
Associated
Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test po rt UUCSSpp sh r 1
1(a) 40960
40975
40977
none
15(b) Any Audits and
Updates Test
(#36)
18 0 b usy station
extension WRN ON release station extension
130(c) None WRN ON test port UU CSSpp sh
257(d) 40973 none
513(e) Station
Present Test
(#48)
WRN OFF test po rt UUCSSpp sh r 2
769 Battery Feed
Test (#35) MIN/
WRN2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
ON test po rt UUCSSpp sh r 2
1025 Looparound
Test (#161) MIN/
WRN2ON test port UUCSSpp l r 2
1281 Conference
Test (#7) MIN/
WRN2ON test port UUCSSpp l r 2
1537 NPE
Crosstalk Test
(#6)
MIN/
WRN2ON test port UUCSSpp l r 2